IE3 - IEC Aluminium Series

( IEC 80 - 112 M Frame - 960 Rpm )

With our efficiency and vast knowledge in this industry, we have come up with a commendable array of Three Phase AC Induction Motor. These induction motors are manufactured by quality-tested components and advance technology in adherence with the international standards. Our offered induction motors are available in diverse stipulations to choose from. Offered induction motors are checked on numerous quality parameters for supplying a defect free range.

Dimensions & Electric Specifications

Drawing And Dimensions Drawing And Dimensions Drawing And Dimensions
FRAME A AA AB AC B BA BB C D DA E EA F FA GA H HA HC HD K L LC
80 125 38 154 157 100 30 125 50 19 19 40 40 8 8 21.5 80 15 154 220 10 270 315
90 S 140 41 174 175 100 30 130 56 24 24 50 50 8 8 27 90 13 160 230 10 310 365
90 L 140 41 174 175 125 30 155 56 24 24 50 50 8 8 27 90 14 160 230 10 33O 385
l00 L 160 48 192 195 140 31.5 175 63 28 28 60 60 8 8 31 100 15 175 240 10 380 445
112 M 190 48 224 205 140 38 177 70 28 28 60 60 8 8 31 112 15 201 270 12 410 480
Drawing And Dimensions Drawing And Dimensions Drawing And Dimensions
FRAME FLANGE
NUMBER
P M N S L LA LB LC LD T D DA E EA F FA GC GA
80 165 200 165 130 12 270 10 220 270 20 3.5 19 19 40 40 8 8 21.5 21.5
90 S 165 200 165 130 12 310 10 25O 310 20 3.5 24 24 50 50 8 8 27 27
90 L 165 200 165 130 12 330 10 270 330 20 3.5 24 24 50 50 8 8 27 27
100 L 215 250 215 180 15 380 11 309 380 24 4 28 28 60 60 8 8 31 31
112 M 215 250 215 180 15 410 11 339 410 24 4 28 28 60 60 8 8 31 31
Drawing And Dimensions Drawing And Dimensions Drawing And Dimensions
FRAME FLANGE
NUMBER
P M N S L LB LC T D DA E EA F FA GC GA
80 100 120 100 80 M6 270 230 270 3 19 19 40 40 6 6 21.5 21.5
90 S 115 140 115 95 M8 310 260 310 3 24 24 50 50 6 6 27 27
90 L 115 140 115 95 M8 330 280 330 3 24 24 50 50 6 6 27 27
l00L 130 160 130 110 M8 380 320 380 3.5 28 28 60 60 6 6 31 31
112 M 130 160 130 110 M8 410 350 410 3.5 28 28 60 60 6 6 31 31
Sl No Kw Frame Size Rpm(Speed) Load Current - Max(Amps) Locked Torque In terms Of Full Load Torque(%) Locked Torque In terms Of Full Load Current (Amps)(IE3) Locked Torque In terms Of Full Load Current (Amps)(IE2) Nominal Eff %(IE3) Nominal Eff %(IE2)
1 0.37 80 960 1.4 160 650 600 73.5 67.6
2 0.55 80 960 1.9 160 650 600 77.2 73.1
3 0.75 90 S 960 2.3 160 650 600 78.9 75.9
4 1.1 90 L 960 3.4 160 650 600 81.0 78.1
5 1.5 100 L 960 4.0 160 650 600 82.5 79.8
6 2.2 112 M 960 5.7 150 750 700 84.3 81.8

Looking for any Powered Motor Solution?
We can customize it for you.

Enquire Now
Send Enquiry